lssphilippines is a leading Friction Loss In A Pipe Manufacturer,and suppliers in Philippines, Friction Loss In A Pipe Manufacturer,and suppliers in South Africa, Friction Loss In A Pipe Algeria (Algiers), Friction Loss In A Pipe Angola (Luanda), Friction Loss In A Pipe Argentina (Buenos Aires), Friction Loss In A Pipe Armenia (Yerevan), Friction Loss In A Pipe Australia (Canberra), Friction Loss In A Pipe Austria (Vienna), Bahrain (Manama), Bangladesh (Dhaka), Bhutan (Thimphu), Bolivia (Sucre), Botswana (Gaborone), Brazil (Brasília), Brunei (Bandar Seri Begawan), Montenegro (Podgorica), Morocco (Rabat), Mozambique (Maputo), Myanmar (Naypyidaw), Namibia (Windhoek), Nepal (Kathmandu), New Zealand (Wellington), Nigeria (Abuja), Oman (Muscat), Palestine (Ramallah), Panama (Panama City), Papua New Guinea (Port Moresby), Paraguay (Asunción), Peru (Lima), Philippines (Manila)¸ Portugal (Lisbon), Qatar (Doha), Rwanda (Kigali), Saudi Arabia (Riyadh), Senegal (Dakar), Serbia (Belgrade), Sierra Leone (Freetown), Slovakia (Bratislava), South Africa (Cape Town) (Pretoria) (Bloemfontein), South Sudan (Juba), Spain (Madrid), Sri Lanka (Sri Jayawardenepura Kotte) (Colombo), Sudan (Khartoum), Syria (Damascus), Tanzania (Dodoma), Thailand (Bangkok), Togo (Lomé), Tonga (Nuku'alofa), Trinidad and Tobago (Port of Spain), Tunisia (Tunis), Turkey (Ankara), Turkmenistan (Ashgabat), Uganda (Kampala), United Arab Emirates (Abu Dhabi), United Kingdom (London), United States (Washington, D.C.).

Static pressure tappings upstream and downstream of the test pipe connect to a water manometer or a hand-held digital pressure meter. The back panel holds the manometer with calibrated scales. 
The Friction Loss in a Pipe apparatus allows students to study the change in the laws of resistance for laminar to turbulent flow and find the critical Reynolds number. The apparatus shows the flow transition point from laminar to turbulent, and is ideal for demonstrations as well as student experiments.
The equipment is a small-bore, straight test pipe on a base plate.
The water manometer measures lower differential pressures in the laminar and lower turbulent flow regions. The pressure meter measures higher pressures in the turbulent flow region. The water manometer includes an air valve and hand-pump. The hand-pump adjusts the datum of the water manometer where necessary. A precision needle valve downstream of the test pipe accurately controls flow rate. 
Students take readings of temperature from a thermometer (supplied) and readings of head from the manometer or the pressure meter. They then use the results to produce charts to help compare actual results with theory.
To perform experiments, students stand the apparatus on the hydraulic bench and fit the Header Tank. For low flow rate experiments, the Header Tank supplies the test pipe. For higher flow rate experiments, the hydraulic bench supplies the test pipe directly. Students set the flow rate, measuring it by timing the collection of water in a measuring vessel (included). 

   