Reverse Osmosis Ultra filtration Unit Manufacturer,Supplier and Exporter in Phillippines

Product Code : LSP-TWL-10813
lssphilippines is a leading Reverse Osmosis Ultra filtration Unit Manufacturer,and suppliers in Philippines, Reverse Osmosis Ultra filtration Unit Manufacturer,and suppliers in South Africa, Reverse Osmosis Ultra filtration Unit Algeria (Algiers), Reverse Osmosis Ultra filtration Unit Angola (Luanda), Reverse Osmosis Ultra filtration Unit Argentina (Buenos Aires), Reverse Osmosis Ultra filtration Unit Armenia (Yerevan), Reverse Osmosis Ultra filtration Unit Australia (Canberra), Reverse Osmosis Ultra filtration Unit Austria (Vienna), Bahrain (Manama), Bangladesh (Dhaka), Bhutan (Thimphu), Bolivia (Sucre), Botswana (Gaborone), Brazil (Brasília), Brunei (Bandar Seri Begawan), Montenegro (Podgorica), Morocco (Rabat), Mozambique (Maputo), Myanmar (Naypyidaw), Namibia (Windhoek), Nepal (Kathmandu), New Zealand (Wellington), Nigeria (Abuja), Oman (Muscat), Palestine (Ramallah), Panama (Panama City), Papua New Guinea (Port Moresby), Paraguay (Asunción), Peru (Lima), Philippines (Manila)¸ Portugal (Lisbon), Qatar (Doha), Rwanda (Kigali), Saudi Arabia (Riyadh), Senegal (Dakar), Serbia (Belgrade), Sierra Leone (Freetown), Slovakia (Bratislava), South Africa (Cape Town) (Pretoria) (Bloemfontein), South Sudan (Juba), Spain (Madrid), Sri Lanka (Sri Jayawardenepura Kotte) (Colombo), Sudan (Khartoum), Syria (Damascus), Tanzania (Dodoma), Thailand (Bangkok), Togo (Lomé), Tonga (Nuku'alofa), Trinidad and Tobago (Port of Spain), Tunisia (Tunis), Turkey (Ankara), Turkmenistan (Ashgabat), Uganda (Kampala), United Arab Emirates (Abu Dhabi), United Kingdom (London), United States (Washington, D.C.).

Reverse Osmosis Ultrafiltration Unit
Description:-
Connection to cooling water and a suitable electrical supply is all that is required for normal operation. 
Comprehensive instrumentation is provided with digital meters displaying temperatures and system pressure. 
This is fully self-contained in a mobile cabinet.
All parts in contact with the process fluid are constructed from hygienic design materials such as stainless steel, PTFE and silicone rubber.
In addition to the membrane module, the cabinet also houses feed and permeate tanks, a plate heat exchanger and positive displacement pumps. 
The RO/UF unit has an efficient clean-in-place facility and is easily dismantled for servicing or maintenance.

It uses a  membrane module which accommodates all PCI membrane types. 
Membranes can be installed or removed rapidly for use in either process.
The unit is supplied with a pack of both R.O. membranes and U.F. membranes.
The filtration membranes differ only in length and quantity from those installed in the full-scale plant. 
Using small quantities of process fluid, operating parameters can be established and then optimized to effect a confident transition to full-scale.

Specification:-
Tubeside Volume: 75ml
Typical Permeate Flow: 5-50ml/min 
Flowrates: 30, 18, 15 and 9l/m
Pressures: Variable up to 55 bar
Diameter: 1.25cm
Area: 0.024m2
Feed Tank Capacity: 15 litres
Permeate Tank Capacity: 15 litres

   

Office Address

Lss Philippines

Works: 214, Calamba St, Santa Mesa Heights, Quezon City, 1114
Metro Manila, Philippines